Updated November 2026. This page lists official exposure limits and precautionary guidelines, with their sources, so you can compare them with your own measurements. EMR Shielding Solutions does not give medical advice. For health questions, please talk to your doctor.
Three kinds of values
- Official exposure limits and reference levels are set or published by governments and international bodies (FCC in the United States, Health Canada Safety Code 6, ICNIRP, and EU Council Recommendation 1999/519/EC).
- Precautionary guidelines, such as the Building Biology guidelines SBM-2024, are much lower. They are not government limits.
- EMR's recommended levels for bedrooms are the levels we suggest aiming for when you shield a bedroom.
Official exposure limits and reference levels (general public)
| Source | RF at 900 MHz (cell) | RF at 2.4 GHz (Wi-Fi) | Electric field, 60 Hz | Magnetic field, 60 Hz |
|---|---|---|---|---|
| FCC, 47 CFR 1.1310 (United States) | 6 W/m² | 10 W/m² | No FCC limit | No FCC limit |
| Health Canada Safety Code 6 (2015) | about 2.74 W/m² | about 5.35 W/m² | Not covered | Not covered |
| ICNIRP 2020 (RF) and ICNIRP 2010 (low frequency) | 4.5 W/m² | 10 W/m² | about 4.17 kV/m | 200 µT (2,000 mG) |
| EU Council Recommendation 1999/519/EC | 4.5 W/m² | 10 W/m² | about 4.17 kV/m | about 83 µT (833 mG) |
1 W/m² = 1,000,000 µW/m². RF limits depend on frequency; the columns are examples. Official RF limits are averaged over time (6 to 30 minutes), while many meters show peak values, so a single peak reading is only a rough comparison. Canada has no federal limit of its own for 60 Hz fields; Health Canada refers to the ICNIRP guidelines.
Building Biology guidelines for sleeping areas (SBM-2024)
| Rating | RF (peak) | Electric field, with ground reference | Magnetic field |
|---|---|---|---|
| No anomaly | below 0.1 µW/m² | below 1 V/m | below 0.2 mG |
| Slight anomaly | 0.1 to 10 µW/m² | 1 to 5 V/m | 0.2 to 1 mG |
| Severe anomaly | 10 to 1,000 µW/m² | 5 to 50 V/m | 1 to 5 mG |
| Extreme anomaly | above 1,000 µW/m² | above 50 V/m | above 5 mG |
SBM-2024 is the 9th edition (August 2024) of the Building Biology Evaluation Guidelines by Baubiologie Maes and the Institut für Baubiologie + Nachhaltigkeit (IBN). Its potential free electric field values are lower (slight anomaly 0.3 to 1.5 V/m). The guideline itself says its values are meant as a guide.
EMR's recommended levels for bedrooms
| Field | EMR's recommended level |
|---|---|
| RF | below 70 mV/m (about 13 µW/m²) |
| Electric field | below 5 V/m, measured with ground reference |
| Magnetic field | below 1 mG (0.1 µT) |
These are practical targets for a shielding project, not health or safety limits. Handheld meters give a guide: measure at the same spot, holding the meter the same way, before and after shielding, and compare the change.
Converting units
Far from the source, RF power density and field strength convert as S = E² / 377, with S in W/m² and E in V/m. For example, 70 mV/m is about 13 µW/m², and 200 mV/m is about 106 µW/m². Close to an antenna this conversion is only approximate.
Sources
- FCC, 47 CFR 1.1310: ecfr.gov
- Health Canada, Safety Code 6 (2015): canada.ca
- Health Canada, power lines and electrical appliances: canada.ca
- ICNIRP 2020 RF guidelines: icnirp.org; ICNIRP 2010 low frequency guidelines: icnirp.org
- EU Council Recommendation 1999/519/EC: eur-lex.europa.eu
- Building Biology SBM-2024: buildingbiology.com